banner
Home » Product > Lubrication Pump > Electric Lubrication Pump
Product Categories

Single-line Dry Oil Pump

Ⅰ . Overview Type DB-63 single line grease pump applies to the small sized single line grease centralized lubricating system with relatively lower lubricating frequency, lubricating points under 80 and PN of 10Mpa. It is a supplies and delivers lubricating grease to each lubricating point...

Send InquiryChat Now

image002.jpg . Overview
 Type DB-63 single line grease pump applies to  the small sized single line grease centralized lubricating system with  relatively lower lubricating frequency, lubricating points under 80 and PN of  10Mpa. It is a supplies and delivers lubricating grease to each lubricating  point through a piece-type grease feeder.
 Type DBZ-63 single line grease pump can be used  for the lubricating points with relatively longer lubricating cycle or of  relatively disperser equipment. Lubricating grease is filled directly by a  grease feeding gun. It is especially suitable for the transportation machinery  equipment used in ports and docks.




. Technical parameters

Model

Nominal pressure (MPa)

Rated flow (ml/min)

Volume of grease    storage (L)

Diameter of plunger (mm)

Number of plunger

Motor

Weight (kg)

Model

Power

Speed

DB-63

10

63

8

8

4

A06324 B5

0.25

1400

23

DBZ-63

4

52

 Use  grease with cone penetration 250~350(25℃,150g) 1/10mm (NLGI0#~2#).


. Descriptions of model


blob.png

 

. Dimensions

blob.png

blob.png

blob.png


. Use instruction

  1. This type single line grease pump should be  installed in the place with appropriate environmental temperature and less dust  for the convenience of grease supplementing, adjustment, inspection and repair  & maintenance.

  2. Add 1 liter 50# mechanical oil to the reduction  gearbox before use.

  3. Supplementing grease into grease conservator  must be done by using SJB-D60 manual grease filling pump or DJB-200 electric  grease filling pump from the grease inlet of the grease conservator. It is  strictly forbidden to start grease pump when there is no lubricating grease in  the grease conservator.

  4. Connect the motor in accordance with the  rotation direction indicated on the fan shell of motor.  Reversal is forbidden.

  5. The filter screen of grease inlet should be  washed regularly.

  6. The pressure regulating value on the pump body  can be adjusted arbitrarily within the scope of 0~10Mpa which should not exceed  the PN 10Mpa of pump is use.

  7. When the pressure of pump fluctuates or grease  supply is abnormal, the air discharge screw on the pump body can be loosened.  When air is discharged and grease spills over normally, the air discharge screw  can be tightened immediately.

  8. Single line grease pump should be kept clean.  Opening the cover to supplement grease is strictly forbidden for avoidance of  dirty substance to enter pump body and influencing normal working.

Hot Tags: single-line dry oil pump, China, manufacturers, cheap, for sale